Availability: | |
---|---|
Quantity: | |
HFM900 Turbine flow sensor (hereinafter referred to as the sensor) is based on the principle of torque balance and belongs to the speed flow meter. The sensor has the characteristics of simple structure, light weight, high precision, good repeatability, sensitive response, easy installation and maintenance, etc. It is widely used in petroleum, chemical industry, metallurgy, water supply, paper making and other industries, and is an ideal instrument for flow measurement and energy saving.
Sensor and display instrument matching use, suitable for measuring closed pipe and stainless steel 1Cr18Ni9Ti, 2Cr13 and corundum Al2O3, carbide does not corrode, and no fiber, particles and other impurities of the liquid. If it is matched with the display instrument with special functions, it can also carry out quantitative control, excessive alarm, etc. The explosion-proof type (ExmIIT6) of this product is selected, which can be used in the environment with explosion danger.
The sensor is suitable for the medium with viscosity less than 5×10-6m2/s at the working temperature. For the liquid with viscosity greater than 5×10-6m2/s, the sensor should be used after solid liquid calibration.
If the user needs a special form of sensor, can negotiate the order, need explosion-proof sensor, in the order to explain.
HFM900 Turbine flow sensor (hereinafter referred to as the sensor) is based on the principle of torque balance and belongs to the speed flow meter. The sensor has the characteristics of simple structure, light weight, high precision, good repeatability, sensitive response, easy installation and maintenance, etc. It is widely used in petroleum, chemical industry, metallurgy, water supply, paper making and other industries, and is an ideal instrument for flow measurement and energy saving.
Sensor and display instrument matching use, suitable for measuring closed pipe and stainless steel 1Cr18Ni9Ti, 2Cr13 and corundum Al2O3, carbide does not corrode, and no fiber, particles and other impurities of the liquid. If it is matched with the display instrument with special functions, it can also carry out quantitative control, excessive alarm, etc. The explosion-proof type (ExmIIT6) of this product is selected, which can be used in the environment with explosion danger.
The sensor is suitable for the medium with viscosity less than 5×10-6m2/s at the working temperature. For the liquid with viscosity greater than 5×10-6m2/s, the sensor should be used after solid liquid calibration.
If the user needs a special form of sensor, can negotiate the order, need explosion-proof sensor, in the order to explain.
Features
Cemented carbide bearing thrust type,
Better accuracy, wear resistance
Simple structure, firm
Convenient disassembly and assembly.
Features
Cemented carbide bearing thrust type,
Better accuracy, wear resistance
Simple structure, firm
Convenient disassembly and assembly.
Technical Parameters
Aperture Diameter | DN4-DN200 |
Flange Standard | Meet GB/T9119-2000standard ,other standards can be customized |
Rated Pressure Grade | DN4~DN20,6.3MPa; DN25~DN80, 2.5MP, DN100~200, 1.6Mpa |
Impeller material | Bidirectional steel impeller, SS316L can customize |
Ingress Protection | IP65 |
Accuracy Grade | 0.5 grade/1.0 grade |
Medium Temperature | -10~80℃ |
LCD display | No display or LCD display selected |
Supply Voltage | Voltage +5-24VDC, current: ≤10mA.; battery supply selected |
Output | Pulse, Current 4~20mA, customized for RS485 and HART |
Environment temperature | -20~+55℃ |
Technical Parameters
Aperture Diameter | DN4-DN200 |
Flange Standard | Meet GB/T9119-2000standard ,other standards can be customized |
Rated Pressure Grade | DN4~DN20,6.3MPa; DN25~DN80, 2.5MP, DN100~200, 1.6Mpa |
Impeller material | Bidirectional steel impeller, SS316L can customize |
Ingress Protection | IP65 |
Accuracy Grade | 0.5 grade/1.0 grade |
Medium Temperature | -10~80℃ |
LCD display | No display or LCD display selected |
Supply Voltage | Voltage +5-24VDC, current: ≤10mA.; battery supply selected |
Output | Pulse, Current 4~20mA, customized for RS485 and HART |
Environment temperature | -20~+55℃ |
HFM900 Turbine flow sensor (hereinafter referred to as the sensor) is based on the principle of torque balance and belongs to the speed flow meter. The sensor has the characteristics of simple structure, light weight, high precision, good repeatability, sensitive response, easy installation and maintenance, etc. It is widely used in petroleum, chemical industry, metallurgy, water supply, paper making and other industries, and is an ideal instrument for flow measurement and energy saving.
Sensor and display instrument matching use, suitable for measuring closed pipe and stainless steel 1Cr18Ni9Ti, 2Cr13 and corundum Al2O3, carbide does not corrode, and no fiber, particles and other impurities of the liquid. If it is matched with the display instrument with special functions, it can also carry out quantitative control, excessive alarm, etc. The explosion-proof type (ExmIIT6) of this product is selected, which can be used in the environment with explosion danger.
The sensor is suitable for the medium with viscosity less than 5×10-6m2/s at the working temperature. For the liquid with viscosity greater than 5×10-6m2/s, the sensor should be used after solid liquid calibration.
If the user needs a special form of sensor, can negotiate the order, need explosion-proof sensor, in the order to explain.
Features
Cemented carbide bearing thrust type,
Better accuracy, wear resistance
Simple structure, firm
Convenient disassembly and assembly.
Technical Parameters
Aperture Diameter | DN4-DN200 |
Flange Standard | Meet GB/T9119-2000standard ,other standards can be customized |
Rated Pressure Grade | DN4~DN20,6.3MPa; DN25~DN80, 2.5MP, DN100~200, 1.6Mpa |
Impeller material | Bidirectional steel impeller, SS316L can customize |
Ingress Protection | IP65 |
Accuracy Grade | 0.5 grade/1.0 grade |
Medium Temperature | -10~80℃ |
LCD display | No display or LCD display selected |
Supply Voltage | Voltage +5-24VDC, current: ≤10mA.; battery supply selected |
Output | Pulse, Current 4~20mA, customized for RS485 and HART |
Environment temperature | -20~+55℃ |