Home » Products » Pressure Sensors » Pressure Gauge » Clean Air Digital Pressure Switch HVAC Cleanroom Control

Clean Air Digital Pressure Switch HVAC Cleanroom Control

The HP3000 Multi-functional Digital Display Differential Pressure Transmitter is a professional pressure monitoring instrument designed for clean air and non-flammable, non-corrosive gas measurement, with a high accuracy of ±0.5%FS and long-term stability of ±0.1%FS/year.
Availability:
Quantity:
facebook sharing button
linkedin sharing button
whatsapp sharing button
twitter sharing button
pinterest sharing button
sharethis sharing button

Overview

Tailored for industrial air pressure control scenarios, it offers multiple configurable measuring ranges with customizable ranges for specific industrial needs, and supports 3xFS overload resistance and 10xFS damage pressure for safe and reliable operation. The device integrates multiple output modes: 0-10V voltage output, 4-20mA current output, 2-way NO/2-way NC switch alarm output, and RS485 Modbus bus communication, realizing multi-dimensional pressure data transmission and abnormal alarm. Housed in ABS engineering plastic, it adapts to a medium temperature of 0-60℃ and an operating environment of -20℃~+85℃, with a clear LED display for real-time pressure readings in multiple units (Pa/kPa/mbar/inWC/mnWC), providing intuitive and convenient operation for on-site industrial users.

Clean Air Digital Pressure Switch HVAC Cleanroom Control

Key Benefits

Ultra-High Precision & Long-Term Stability 

Adopting advanced industrial sensor technology, the transmitter features a temperature drift coefficient of <0.03%FS/℃, ensuring minimal measurement error caused by temperature changes in industrial environments. Its long-term stability of ±0.1%FS/year reduces frequent calibration work, saving maintenance costs for industrial operators.

Multi-Range & Customizable Measurement 

With four standard differential pressure ranges and support for custom range development, it meets the diverse pressure monitoring needs of different industrial scenarios—from micro-pressure detection in cleanrooms to medium-pressure monitoring in HVAC systems, achieving one device for multiple uses.

Diversified Output & Abnormal Alarm 

Integrated 4-20mA industrial standard current output, 0-10V voltage output, and RS485 Modbus communication enable seamless integration with factory-level automation systems. The 2-way NO/2-way NC switch alarm output triggers immediate alerts for pressure deviations, helping industrial users avoid production risks caused by abnormal pressure.

Wide Industrial Adaptability & Durability 

The ABS engineering plastic housing has excellent anti-corrosion and anti-impact performance, adapting to a wide operating temperature range of -20℃~+85℃. It is specially designed for clean air measurement, with no pollution to the measured gas, meeting the clean requirements of pharmaceutical, semiconductor and food industries.

User-Friendly Operation & Easy Calibration 

The multi-unit switchable LED display shows real-time differential pressure data clearly, even in low-light industrial environments. The device supports simple on-site calibration without professional tools, reducing the operation difficulty for on-site maintenance personnel and improving work efficiency.

Industrial Applications of Digital Differential Pressure Transmitter

The HP3000 Differential Pressure Transmitter is an essential monitoring component for industrial users in air pressure control and clean environment management, widely used in:

Pharmaceutical & Semiconductor Cleanrooms: Maintaining positive/negative pressure balance in cleanrooms to prevent external contamination, ensuring compliance with GMP and semiconductor manufacturing clean standards.

HVAC System Operation & Maintenance: Monitoring pressure differentials in air conditioning ducts and air supply/return systems, identifying system inefficiencies and optimizing energy consumption for commercial and industrial buildings.

Healthcare Isolation Rooms: Maintaining negative pressure in infectious disease isolation rooms and positive pressure in sterile operating rooms to control the spread of airborne pathogens and ensure medical safety.

Industrial Filter Status Detection: Monitoring pressure drops across air filters in dust removal systems, ventilation systems and clean air equipment, prompting timely filter replacement to maintain optimal airflow.

Data Center Cooling Systems: Optimizing air pressure distribution in data center machine rooms, ensuring efficient cooling of server equipment, preventing overheating and reducing energy consumption of cooling systems.

Food Processing & Packaging: Controlling air pressure in clean production areas, preventing dust and microbial contamination, and ensuring food safety and compliance with production hygiene standards.

Laboratory Environmental Control: Monitoring pressure differentials in chemical and biological laboratories, ensuring safe handling of hazardous materials and protecting the health of laboratory personnel.

FAQ

What is the core application value of the HP3000 Differential Pressure Transmitter in cleanrooms?

It accurately monitors the positive/negative pressure difference of cleanrooms in real time, ensuring that the air in the cleanroom flows in a fixed direction, preventing unfiltered air from entering the clean area, and is the core guarantee for maintaining the clean grade of pharmaceutical, semiconductor and other high-precision manufacturing industries.

Can this transmitter realize remote data monitoring and control?

Yes. Equipped with RS485 Modbus bus communication function, it can connect to the industrial Internet of Things and centralized monitoring system, realizing remote real-time viewing of pressure data, historical data query and remote alarm setting for industrial users.

What is the overload and damage pressure performance of the HP3000?

It has 3x full-scale (FS) overload resistance capacity, which can withstand short-term excessive pressure without damage; the damage pressure is 10x FS, ensuring the device's safety in case of accidental pressure surges in industrial on-site environments.

Does the transmitter support multi-unit display and which units are available?

It supports multi-unit switchable display, including Pa, kPa, mbar, inWC and mnWC, covering the common pressure units in the global industrial field, meeting the usage habits of industrial users in different regions.

What is the power supply requirement of the HP3000 Differential Pressure Transmitter?

It adopts a standard industrial DC power supply of 24VDC±3VDC, which is consistent with the power supply specification of most industrial automation equipment, no need for an independent power supply, and easy to integrate into the existing power supply system of the factory.

Parameter

Value

Measuring medium

Air and non-flammable, non-corrosive gases

Medium temperature

0-60°C

Housing

ABS engineering plastic

Operating environment

-20°C to +85°C

Differential pressure range

Various ranges, overload 3xFS, damage pressure 10xFS

Communication output

RS-485

Accuracy

±0.5%FS

Long-term stability

±0.1%FS / year

Temperature drift coefficient

<0.03%FS/°C

Power supply

24VDC ±3VDC


Clean Air Digital Pressure Switch HVAC Cleanroom Control


Leave a Message
Contact Us

Quick Links

Product Category

Contact Us

   No.18, Fenghua Road, Yuhua Economic Development Zone, Nanjing, Jiangsu,China
   +86-17551075580
    info@hjsensor.com