Home » Products » Flow Meters » Flow Meter » HFM400 Pointer-Type Metal Tube Variable Area Flow Meter

HFM400 Pointer-Type Metal Tube Variable Area Flow Meter

Nominal Sizes: DN15, DN25, DN50, DN80, DN100 and DN150
Measured Media: Compatible liquid, gas and steam
Flow Range: Liquid 1.0–150000 L/h; gas 0.05–3000 m³/h
Range Ratio: 10:1 standard; 20:1 special
Indication and Output: Local pointer; optional LCD, 4–20 mA, HART and alarm contact
Wetted Materials: SS304 standard; SS316L, Hastelloy, titanium and PTFE-lined options
Availability:
Quantity:
facebook sharing button
linkedin sharing button
whatsapp sharing button
twitter sharing button
pinterest sharing button
sharethis sharing button

Overview

The HFM400 is a pointer-type metal tube variable area flow meter for measuring the flow of compatible liquids, gases and steam. Its metal measuring tube and local mechanical indicator suit industrial lines where a glass-tube meter would not provide the required pressure, temperature or mechanical protection.

Available nominal sizes include DN15, DN25, DN50, DN80, DN100 and DN150. The meter is particularly useful for small-pipe and low-flow duties, while larger configurations extend the product family to liquid flows up to 150000 L/h and gas flows up to 3000 m³/h.

The standard design provides local pointer indication without direct contact between the measuring element and the external indicator mechanism. Depending on the selected configuration, the HFM400 can also provide a dual-line LCD, two-wire 4–20 mA transmission, HART communication and a dry-contact alarm output.

Each meter must be selected for the actual medium, operating flow, density, viscosity, pressure, temperature, flange standard and required signal. These conditions determine the measuring element, calibrated scale, wetted material and pressure-temperature configuration.


Features

  • It is suitable for measuring the flow rate of medium with small diameter and low velocity

  • Reliable operation, small amount of maintenance, long life

  • Requirements for straight section are not high

  • Wider range ratio of 10:1

  • Double-line LIQUID crystal display, field instantaneous/cumulative flow displa

  • There is a keyboard on the indicator for easy operation and setting

  • All-metal structure, suitable for high temperature, high pressure and strong corrosive mediu

  • Non-contact magnetic coupling transmissio

  • Can be used in inflammable and explosive dangerous occasions

  • Optional DC power supply or battery power supply mode

  • With data recovery, data backup and power down protection functions

  • Multi-parameter calibration function


Product Advantages

Local Flow Indication

The pointer gives operators a direct view of flow at the pipe. It can be used where local indication is sufficient or combined with an electronic output when the signal must also be sent to a PLC, DCS, recorder or remote display.

All-Metal Measuring Structure

The measuring cone, float and process connections form a robust metal flow path. This construction is suitable for process environments where a transparent measuring tube is not preferred. Material compatibility still has to be checked against the medium and cleaning conditions.

Non-Contact Magnetic Coupling

Float movement is transferred through the tube wall by magnetic coupling. There is no mechanical shaft penetrating the measuring tube between the process and the indicator, which separates the pressurized process chamber from the external pointer mechanism.

Practical Piping Requirements

Variable area measurement does not depend on a high-speed turbine rotor or an electromagnetic field. The HFM400 generally needs less straight pipe than many velocity-based meters, but installation disturbances must still be considered. Valves, reducers and pumps should not create unstable flow or float oscillation at the meter inlet.

Configurable Measurement Package

The HFM400 can be configured around local reading, remote transmission, totalization, material selection, pressure class and temperature duty. Optional electronics can include parameter setting, calibration data storage, backup and power-loss protection.


Technical Parameters

Aperture Diameter                

DN15, DN25, DN50, DN80, DN100, DN150                

(other diameters, need consult us and customized)                

Flow Range                

Liquid: 1.0 ~ 150000L /h gas: 0.05 ~ 3000m3/h                

Ratio Range                

10∶1, 20∶1 (Special)                


               

Viscosity of medium                

DN15: < 5mPa. S / DN25: < 250mPa. S                

DN50 ~ DN150: < 300mPa.S                


               

Flange                

GB/T9119-2000standard carbon steel                

(stainless steel optional),other standards can be customized                

Rated Pressure Grade                

DN15, DN25, DN50:4.0MPa (Max 20MPa)                

DN80, DN100, DN150:1.6mpa                

(Max:DN80:10MPa;DN100:6.4 MPa;6:4.0 MPa)                


               

Tube and Float Material                

Default Stainless steel 304, SS316L, Hastelloy (HB and HC), Titanium can be customized, PTFE lining can customized                

Can                

Accuracy Grade                

1.5 grade, 1.0 grade (Special customized)                

Medium Temperature                

Standard -30℃ ~ +120℃, high temperature: 120℃ ~ 350℃                


               

Ambient temperature                

-40℃ ~ 120℃ Remote: -30℃ ~ 60℃                

Storage condition                

-40℃ ~ 85℃ Humidity: ≤85%                

Supply Voltage                

24VDC (12 ~ 36VDC)                

Output                

4 ~ 20mADC (two wire), HART protocol can be attached;                

Alarm dry contact signal                


Pointer Indicator and Display Options

Pointer-Type Indicator

The standard round indicator displays instantaneous flow on a graduated dial. It requires no process penetration for the magnetic coupling and can provide local indication without loop power when no electronic functions are selected.

The pointer scale is prepared for the stated medium and flow unit. Custom scale marking should be defined during ordering when the project uses engineering units or reference conditions other than the standard quotation.

Optional Dual-Line LCD

An electronic indicator can provide a two-line LCD for instantaneous and cumulative flow. Keyboard operation allows permitted parameters to be set at the instrument. This option requires the appropriate transmitter and power configuration and is not part of every pointer-only meter.

Indicator Enclosure

The standard indicator enclosure is specified to IP65 when correctly assembled and installed. Cable glands, covers and unused entries must be sealed as required to maintain enclosure protection. IP65 describes protection against dust and water jets; it does not mean the meter can be submerged.


Industrial Applications

The HFM400 can be configured for flow monitoring in suitable processes across:

  • Petrochemical and chemical processing

  • Iron and steel production

  • Electric power systems

  • Metallurgical and mining operations

  • Light industrial manufacturing

  • Food and beverage utilities

  • Pharmaceutical utility systems

  • Water and wastewater treatment

  • Gas distribution and process skids

  • Steam and thermal-process systems

Application suitability depends on the selected materials, calibrated range, cleanliness of the medium, operating conditions and applicable site requirements.

FAQ

Can a water-calibrated HFM400 measure another liquid?

It may indicate flow, but the original scale may no longer meet its specified accuracy. Density and viscosity change the float position. Provide the new liquid properties and operating temperature so the need for correction, a replacement scale or recalibration can be assessed.

Can the same HFM400 scale be used for air and another gas?

Not without technical evaluation. Gas composition, operating pressure, temperature and selected standard or actual volume conditions affect density and the calibrated result. A gas-specific scale or conversion is normally required.

Why does the pointer stay above zero after flow stops?

Possible causes include deposits on the float or guide, a tilted installation, internal damage, magnetic coupling interference or a pointer mechanism problem. Isolate, depressurize and inspect the meter according to site procedures; do not force the pointer externally.

Can the HFM400 replace an existing meter without changing the pipework?

Only after confirming face-to-face length, flange size, standard, pressure class, facing and flow direction. The replacement scale, material, pressure-temperature rating and electronic outputs must also match the process and control system.

Is pointer accuracy the same as 4–20 mA loop accuracy?

Not necessarily. Local indication and transmitted output may have separate tolerances. The complete loop also includes transmitter conversion, wiring, input resolution and PLC or DCS scaling. Acceptance criteria should identify whether they apply to the dial, current output or complete measurement loop.


Configure Your HFM400

Match the Flow Meter to Your Process Conditions

Send the medium, flow range, density, viscosity, pressure, temperature, pipe size and flange details. HIGHJOIN will review the measuring range, wetted materials, indicator and output configuration for your application.

  • Medium and flow range
  • Density and viscosity
  • Pressure and temperature
  • DN size and flange standard
  • Wetted material
  • Pointer and output options

Complete process data helps avoid an incorrect scale or material selection.