Availability: | |
---|---|
Quantity: | |
HTM128 explosion-proof temperature transmitter is specifically designed for use in hazardous environments where there is a risk of explosion. It supports the use of PT100, PT1000, or thermocouple sensors as the signal measurement components, offering flexibility to accommodate different temperature sensing requirements.
The transmitter features an amplification circuit housed within a robust stainless-steel shell. This circuit converts the sensor signal from the PT100, PT1000, or thermocouple into a standard signal, such as a current or voltage output. The stainless-steel shell ensures protection and integrity of the electronics in hazardous environments.
With its excellent reliability, the HTM128 transmitter is widely used for on-site temperature measurement and control in various industrial processes. It finds applications in industries such as petroleum, chemical, metallurgy, electric power, hydrology, and more, where explosive atmospheres may be present. Its adaptability, flexibility, and diversity make it a trusted solution for temperature monitoring and control in hazardous industrial settings.
HTM128 explosion-proof temperature transmitter is specifically designed for use in hazardous environments where there is a risk of explosion. It supports the use of PT100, PT1000, or thermocouple sensors as the signal measurement components, offering flexibility to accommodate different temperature sensing requirements.
The transmitter features an amplification circuit housed within a robust stainless-steel shell. This circuit converts the sensor signal from the PT100, PT1000, or thermocouple into a standard signal, such as a current or voltage output. The stainless-steel shell ensures protection and integrity of the electronics in hazardous environments.
With its excellent reliability, the HTM128 transmitter is widely used for on-site temperature measurement and control in various industrial processes. It finds applications in industries such as petroleum, chemical, metallurgy, electric power, hydrology, and more, where explosive atmospheres may be present. Its adaptability, flexibility, and diversity make it a trusted solution for temperature monitoring and control in hazardous industrial settings.
Application
On-site temperature measurement and control are crucial in various industries, including:
petroleum
chemical industry
metallurgy
electric power
hydrology, etc.
Application
On-site temperature measurement and control are crucial in various industries, including:
petroleum
chemical industry
metallurgy
electric power
hydrology, etc.
Features:
All stainless-steel housing, protection grade is IP65.
Reverse polarity protection and instantaneous overcurrent and overvoltage protection measures, strong anti-interference, and good long-term stability
High precision and good stability
Supports various process interfaces, easy to install and use on site.
Features:
All stainless-steel housing, protection grade is IP65.
Reverse polarity protection and instantaneous overcurrent and overvoltage protection measures, strong anti-interference, and good long-term stability
High precision and good stability
Supports various process interfaces, easy to install and use on site.
Technical Parameters
Measuring Temperature Range | -40~1500℃ |
Measuring Medium | various liquid, gas, or steam compatible with 304 or 316L stainless steel |
Accuracy | ±0.5%FS |
Long-term Stability | ±0.2%FS/year |
Insertion Depth | customization |
Mounting Thread | customization |
Operation Temperature | -30~70℃(normal type); -20~60℃(Explosion-proof type) |
Storage Temperature | -30~85℃ |
Supply Voltage | 24VDC |
Output Signal | 2-wire 4~20mADC,3-wire voltage , 3-wire PT100 or RS485 etc |
Protection Grade | IP65 |
Electrical Connection | Cable gland with terminals inside shell |
Explosion-proof | ExdⅡCT6 Gb |
Technical Parameters
Measuring Temperature Range | -40~1500℃ |
Measuring Medium | various liquid, gas, or steam compatible with 304 or 316L stainless steel |
Accuracy | ±0.5%FS |
Long-term Stability | ±0.2%FS/year |
Insertion Depth | customization |
Mounting Thread | customization |
Operation Temperature | -30~70℃(normal type); -20~60℃(Explosion-proof type) |
Storage Temperature | -30~85℃ |
Supply Voltage | 24VDC |
Output Signal | 2-wire 4~20mADC,3-wire voltage , 3-wire PT100 or RS485 etc |
Protection Grade | IP65 |
Electrical Connection | Cable gland with terminals inside shell |
Explosion-proof | ExdⅡCT6 Gb |
HTM128 explosion-proof temperature transmitter is specifically designed for use in hazardous environments where there is a risk of explosion. It supports the use of PT100, PT1000, or thermocouple sensors as the signal measurement components, offering flexibility to accommodate different temperature sensing requirements.
The transmitter features an amplification circuit housed within a robust stainless-steel shell. This circuit converts the sensor signal from the PT100, PT1000, or thermocouple into a standard signal, such as a current or voltage output. The stainless-steel shell ensures protection and integrity of the electronics in hazardous environments.
With its excellent reliability, the HTM128 transmitter is widely used for on-site temperature measurement and control in various industrial processes. It finds applications in industries such as petroleum, chemical, metallurgy, electric power, hydrology, and more, where explosive atmospheres may be present. Its adaptability, flexibility, and diversity make it a trusted solution for temperature monitoring and control in hazardous industrial settings.
Application
On-site temperature measurement and control are crucial in various industries, including:
petroleum
chemical industry
metallurgy
electric power
hydrology, etc.
Features:
All stainless-steel housing, protection grade is IP65.
Reverse polarity protection and instantaneous overcurrent and overvoltage protection measures, strong anti-interference, and good long-term stability
High precision and good stability
Supports various process interfaces, easy to install and use on site.
Technical Parameters
Measuring Temperature Range | -40~1500℃ |
Measuring Medium | various liquid, gas, or steam compatible with 304 or 316L stainless steel |
Accuracy | ±0.5%FS |
Long-term Stability | ±0.2%FS/year |
Insertion Depth | customization |
Mounting Thread | customization |
Operation Temperature | -30~70℃(normal type); -20~60℃(Explosion-proof type) |
Storage Temperature | -30~85℃ |
Supply Voltage | 24VDC |
Output Signal | 2-wire 4~20mADC,3-wire voltage , 3-wire PT100 or RS485 etc |
Protection Grade | IP65 |
Electrical Connection | Cable gland with terminals inside shell |